The strain sensors can be applied to monitor strain changes in various structures for a very long period of time.
Strain sensors use the sensivity of fiber grating to measure strain. FBG is fixed inside a stainless steel box between two anchor points. The box is made with a sliding mechanism which allows the two ends to move freely relative to each other.
- Center Wavelength nm 1510-1590
- Custom strain measurement range με +/-1500
- Custom precision 1%
- Temperature range -5-80
- Dimension mm : 12 * 102 / 78(L) * 14(L) * 7(H)